AGILENT 6030A PDF

HP / Hewlett Packard / Agilent Used A Autoranging System Power Supplies, Refurbished – A, A, A, A, A, A, A- Used Test. 19 results Here you will find a large selection of new and used Keysight Technologies ( Agilent HP) A listed at special prices. Although some items match. Find great deals for Hp/agilent A System Autoranging DC Power Supply v 17a. Shop with confidence on eBay!.

Author: Goltilabar Dairr
Country: Puerto Rico
Language: English (Spanish)
Genre: Art
Published (Last): 28 May 2012
Pages: 487
PDF File Size: 12.68 Mb
ePub File Size: 13.55 Mb
ISBN: 261-6-54957-265-8
Downloads: 71709
Price: Free* [*Free Regsitration Required]
Uploader: Kagahn

Send to a Friend. Your Email Address Email is not vaild. Remind me later Go. Most of the extensive programmable instruction set can be simulated with front panel controls, thus facilitating design and debugging of system hardware and software. To use this feature, you will also need to order a serial link cable for each unit to be added to the chain, with the first unit connected directly to HP-IB.

This feature requires programming in TMSL mode. Analog programming inputs and monitoring terminals are provided on the rear panel in addition to the HP-IB programming capabilities. Potentially harmful conditions, such as overtemperature and high or low ac input, will trigger aglient power supply to automatically down-program to zero output.

This status can also be read back to the computer over the HP-IB and can be used to generate interrupts. About Avalon Test Equipment. Rack mount kit for single unit. The Dealer Directory is intended for visitors to 6030s specific business inquiries and should not be used to send bulk emails. Remind me later Send. Because of the delicate nature of most loads, these system power supplies provide several different types of protection.

Often, control and monitoring via the front panel is very useful during system development, but not needed afterwards. Your password must be at least 8 characters long and contain at least one uppercase letter.

  ENCYKLOPEDIA WSPCZESNEJ BRONI PALNEJ PDF

Rack mount kit for two units side by side. Production procedures sometimes require the operator to adjust the output voltage or current of a power supply locally with the front panel controls. If your application requires more power than the output capability of a single unit, you can use an auto-series connection for greater output voltage or an auto-parallel connection for greater output current.

If this is done, programmed agilejt can be set to limit the available adjustment range to a safe margin. Would you like to send a Request to the Sellers before you leave?

Front Panel Control Protection Features. A conventional power supply subsystem capable of monitoring and controlling power supply voltage and current requires a variety of hardware in addition to the actual supply.

You can send up to 10 dealer emails at a time, and up to 30 per day. The A Autoranging DC Power Supply is part of the x family of power supplies which provide a wide and continuous range of output voltage and current levels at the rated 630a output. A special modification is available for HP models A, A and A to ensure stable operation when operating into inductive loads up to 10 H.

The standard serial link cable is 2 meters 6. This often allows both present and future requirements to be satisfied with fewer supplies, also reducing the number of instruments in the system.

Operation is possible with up to 2. Agilent basic DC power supplies offer essential features for a tight budget. Agilent A 1ch, 0 to Vdc, 0 to 17A, W. Fewer instruments mean less rack space, easier calculation of system specifications, quicker configurations, higher system reliability, more rapid troubleshooting, and simpler software.

Send a message to this seller. The monitoring terminals present volt buffered signals which are proportional to the output voltage and current.

Keysight Technologies (Agilent HP) A used or new for sale at used-line

This applies to HP A and A only. A blank filler panel is supplied when this option is ordered with HP A and A. Please Call Rack mount kit for single unit. Remote sensing can be used to maintain the CV load effect specification at the load with up to 0. During system operation, if local control is not needed, the front panel controls can be disabled with a computer command.

  CONDUITE PROJET WEB BORDAGE PDF

Would you like agilenr receive announcements about auctions and special sales?

The built-in overvoltage protection circuit is adjustable with a front panel control. View Cart My Account. In this case, the FOLDBACK feature, if enabled, would be able to serve as an over-current protection circuit and down-program the power supply automatically. Zero to full xgilent voltage or current can be programmed with either volt voltage signals, or ohm resistance signals. Ordering your power supplies with Option significantly decreases the cost.

Providing the finest test equipment solutions since 1992

The Agilent W, single-output A is an efficient solution for large demanding test systems that saves rack space and reduces system complexity. If the system is reproduced without further development, power supplies without front panel controls and meters Option can then be used except HPA.

The set trip level can be displayed on the front panel meter and also can be read back over the HP-IB, thus making adjusting the level easy. Use this form to quickly and easily send an agileent to a dealer. Programmable Features System Configuration. As autoranging power supplies, these models can provide a wide 6300a continuous range of voltage and current combinations at the maximum rated power.

Up to 16 power supplies can share one HP-IB address, while still providing full independent control, when connected with a modular telephone-style cable.